| 1.Input voltage range |
85 - 265VAC (47 - 63Hz), 120 - 330VDC universal input |
| 2.Power factor |
0.99 (typ) 100VAC at full load, 0.95 (typ) 200VAC at full load |
| 3.Cooling |
JWS50 - JWS150 : Convection cooling /
JWS300&JWS600 : Forced air cooling by internal fan |
| 4.Operating ambient temperature |
JWS50 - JWS150 : -10 - +60ºC (Standard mounting) Output derating
: 100% at -10 - +50ºC, 60% at +60ºC
JWS300 - JWS600 : 100% at -10 - +50ºC, 60% : +60ºC, 55% at +65ºC |
| 5.Withstand voltage |
Input-output : 3kVAC (20mA), Input-chassis : 2kVAC (20mA), Output-chassis : 500VAC (100mA) for 1min. |
| 6.EMI |
Built to meet EN55011-B, EN55022-B, VCCI-class 2 and FCC-B |
| 7.EMS |
Built to meet EN55011-B, EN55022-B, VCCI-class 2 and FCC-B |
| 8.PFHC |
Built to meet EN61000-3-2 |
| 9.Safety standard |
Approved by UL1950, CSA950, EN60950 and VDE0160,Built to meet DENTORI |
| 10.Functions |
Over voltage protection, Over current protection, Remote sensing (JWS100 - JWS600), Remote on/off control (JWS300 - 600) |
| 11.Option |
Remote on/off control, Input/output connector (JWS50,75), Cover, Mounting sheet metal |